The RAL colour codes for our products are:

Terrain Grey RAL 7023

Black RAL 9005

White RAL 9010

Rustic RAL 8016

For more information about our drainage systems please click here

Terrain FUZE HDPE Drainage System may be used to convey liquids with a maximum temperature of 80 degrees when subjected to continuous flow. Intermittent discharges of up to 95 Degrees Celsius may occur provided they are of less than two minutes duration. For further information please see our Terrain FUZE HDPE Technical Manual.

Terrain PVC Soil and Waste Drainage Systems may be used to convey liquids with a maximum temperature of 76 degrees when subjected to continuous flow. Intermittent discharges of up to 100 degrees Celsius may occur provided they are of less than two minutes duration. For further information see our Above Ground Technical Manual.

Our Terrain Solvent Weld Soil 100 and Push-fit Soil 100P drainage systems are made from unplasticised Polyvinyl Chloride (uPVC or PVC-u). To see the range click here

Our Terrain Solvent Weld Waste 200 system is manufactured from Modified unplasticised Polyvinyl Chloride (MuPVC). To see the range click here

Our Terrain Push-fit Waste 300 system is manufactured from Polypropylene (PP). To see the range click here

Our Terrain Solvent Weld Waste 600 System is manufactured from Acrylonitrile Butadiene Styrene (ABS). To see the range click here

Our Terrain FUZE HDPE Soil and Waste Drainage System is manufactured from High Density Polyethylene (HDPE). To see the range click here

Information about the chemical resistance of our piping systems can be found here

Information about our BIM libraries can be found in our Terrain Technical Bulletin here. For further information please contact Carl.Brunger@polypipe.com

 

Our products are available to buy through selected commercial builders merchants.  To find a stockist near you use our postcode search here. Find a stockist

For full details of how to adapt to other materials within a drainage system please see the following Technical Bulletin on Adapting to other Materials.

Our standard lead time for Fabrication orders are 21 days from date of order.  For more information about our Fabrication Service please visit our Fabrication page here Terrain Fabrication Service

Our standards and certifications for our drainage systems can be found at the back of our price list or online here Standards and Certifications

For pipe sizes up to 63mm there should be an expansion coupling every 5m. We would suggest one every floor on a vertical stack. For pipe sizes above 63mm, so 75mm and above an expansion coupling should be installed every 2m. However, any change in direction where the maximum distance between fixed points exceeds 1m you should install an expansion coupling.

For a more detailed answer and for further reference please see our Technical Bulletin below on Terrain FUZE HDPE Thermal Expansion.

Issue 8 2017 - Terrain FUZE HDPE Thermal Expansion

For pipe sizes from 82-160mm, there should be an expansion coupling every 4m . We would suggest one every floor on a vertical stack. For pipe sizes 32-50mm the maximum distance is 2m. However, any change in direction where the maximum distance between fixed points exceeds 1m you should install an expansion coupling.

For a more detailed answer and for further reference please see our Technical Bulletin below on Controlling Thermal Movement in PVC drainage systems

Issue 3 2017 - Bracketry and expansion in PVC drainage